LiveNX 6210 Technical Specifications
Specification
|
Description
|
---|---|
Base
|
OEM PowerEdge R7625 XL Server
|
Chassis
|
3.5" Chassis with up to 12 SAS3/SATA Drives with 2x2.5" Rear, LP Adapter PERC 12
|
Motherboard
|
OEM PowerEdge R7625 XL Motherboard
|
Processor
|
(2) AMD Epyc 9354 Processors 3.25 GHz 32C/64T
|
Memory
|
(16) 64 GB RDIMM, 4800 MT/s Dual Rank
|
RAID/Internal Storage Controllers
|
PERC H965i Adapter Low Profile, 8 GB NV Cache
|
Hard Drive
|
(12) 20 TB Hard Drive SAS 12 Gbps 7.2K 512e 3.5 in Hot-Plug, AG Drive
(2) 600 GB Hard Drive SAS ISE 12 Gbps 10k 512n 2.5in Flex Bay
|
Network Adapters
|
Broadcom 57416 Dual Port 10GbE BASE-T Adapter, OCP NIC 3.0
Broadcom 5720 Dual Port 1GbE LOM
|
Fans
|
Very High Performance Fan x6
|
Power Supply
|
Dual, Hot-plug, Redundant Power Supply (1+1), 2400W
|
Power Cords
|
C13 to C14, PDU Style, 12 AMP, 6.5 Feet (2m) Power Cord, North America
|
PCIe Riser
|
Riser Config 7
- 4 x8 FH (Gen5)
- 2 x16 LP
|
Embedded Systems Management
|
iDRAC9, Enterprise
|
Quick Sync
|
None
|
Rack Rails
|
ReadyRails Sliding Rails Without Cable Management Arm
|
PSU Specifications:
PSU
Class
Heat Dissipation (Maximum)
Frequency
Voltage
|
2400 W Mixed Mode
Platinum
9000
50/60
100-240 V AC
|
Temperature Specifications A2:
|
|
Allowable continuous operations
|
|
Temperature range for altitudes < = 900 m (< = 2953 ft)
|
10–35°C (50–95°F) with no direct sunlight on the equipment
|
Humidity percent range (non-condensing at all times)
|
8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point
|
Operational altitude de-rating
|
Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft)
|
Temperature Specifications A3:
|
|
Allowable continuous operations
|
|
Temperature range for altitudes < = 900 m (< = 2953 ft)
|
5–40°C (41–104°F) with no direct sunlight on the equipment
Excursion Limited Operation
- 5-35°C (41-95°F) Continuous Operation
- 35-40°C (95-104°F) 10% Annual Runtime
|
Humidity percent range (non-condensing at all times)
|
8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point
|
Operational altitude de-rating
|
Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900 m (2953 Ft)
|
Temperature Specifications A4:
|
|
Allowable continuous operations
|
|
Temperature range for altitudes < = 900 m (< = 2953 ft)
|
5–45°C (41–113°F) with no direct sunlight on the equipment
Excursion Limited Operation
- 5-35°C (41-95°F) Continuous Operation
- 35-40°C (95-104°F) 10% Annual Runtime
- 40-45°C (104-113°F) 1% Annual Runtime
|
Humidity percent range (non-condensing at all times)
|
8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
|
Operational altitude de-rating
|
Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft)
|
Relative Humidity Specifications:
|
|
Storage
|
8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point. Non-condensing at all times.
|
Operating
|
10% to 80% relative humidity with 29°C (84.2°F) maximum dew point.
|
Maximum Vibration Specifications:
|
|
Operating
|
0.21 Grms at 5 Hz to 500 Hz for 10 minutes (all operation orientations)
|
Storage
|
1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
|
Maximum Shock Pulse Specifications:
|
|
Operating
|
Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms.
|
Storage
|
Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.
|